The applicability of the Maximum Power-point of Microbial Fuel Cells: Influence of Potential Scan rate and real-time external Load

dc.contributor.authorSimeon, Meshack Imologie
dc.contributor.authorFreitag, Ruth
dc.date.accessioned2025-05-03T17:03:32Z
dc.date.issued2021-09-15
dc.description.abstractPerformance evaluation of a microbial fuel cell (MFC) is usually done with linear sweep voltammetry (LSV) [1] at a given potential scan rate (PSR) [2]. This evaluation does not often reflect the long-term performance of the MFC under real-time external loads [1]. In this study, the performance of a single-chamber MFC was evaluated with three external loads (1206, 470, and 270 Ohms) calculated from LSV maximum power point (MPP) with three PSRs (0.1, 0.5, and 1 mV/s). The estimated power from the MPP in ascending order of PSR was 61.96, 87.88, and 166.68 mW/m2 at 116.5, 229.6, and 403 mA/m2, respectively. The average power obtained with 1206, 470, and 270 Ohms in the first two hours of operation was 73 + 16.7, 36.3 + 42, and 88.5 + 120.1 mW/m2 at current densities of 124.6 + 14.3, 121.2 + 73.4, and 232.6 + 176.2 mA/m2, respectively. The result showed that overestimation was more pronounced at higher PSRs. Although the MFC was initially underestimated at 0.1 mV/s, this PSR more accurately reflects the true and applicable estimate of the long-term performance of the MF vC. These results are explicitly beneficial for ethe lectrochemical estimation of the actual performance of MFCs under real-time external loads
dc.identifier.citation19. Simeon Meshack Imologie and Ruth Freitag. “The applicability of the Maximum PowerPoint of Microbial Fuel Cells: Influence of Potential Scan rate and real-time external Load.” 5th European meeting of the International Society for Microbial Electrochemistry and Technology, Girona, Spain.
dc.identifier.urihttp://repository.futminna.edu.ng:4000/handle/123456789/1747
dc.language.isoen
dc.publisherinternational Society for microbial Electrochemistry amd Technology-ISMET
dc.relation.ispartofseriesISMET
dc.subjectmaximum power
dc.subjectmicrobial fuel cell
dc.subjectexternal load
dc.subjectpotential scan rate
dc.titleThe applicability of the Maximum Power-point of Microbial Fuel Cells: Influence of Potential Scan rate and real-time external Load
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
2 Simeon conference papert-EU ISMET.pdf
Size:
207.76 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: